· The pistoning design
· Adjusting the flow through the nozzle calibration
· The sealed AMP electrical connector
· The possibility of any configuration of connecting through dedicated adapters and power busses and separating
· Material of high magnetic permeability and high induction saturation
· Maximum rate - 125 Nl / min (at a pressure of 1.0 bar)
· Coil resistance - 1,9 Ω
· Opening time - 1.9 ms
· Closing time - 1.2 ms
· Maximum supply pressure - 4.0 bar
· Operating temperature -35 ° C to + 125 ° C · Life
- more than 400 million cycles
It is available in single version and for installation in terminal 2,3,4